27 Nisan 2008 Pazar

Compressor Crankcase Heaters

Description Part No. Watts Application
Universal hermetic compressor sump heater-240 volt ME786-A 54 Universal
Maneurop sump heater - 200 to 600 volt 7773001 35 Maneurop only

JRM Evaporator Fan Motors

BOC Part No.

Suits makes
Suits models
Rotation
Amps
Description
J06BM19 Muller
(replaces J06RF07)
CSN, CSL ACW 0.3 3/16" Shaft
(3/4" Stack)

J06BM15

Kirby
(replaces J06RF08)
KC, TA, TL CW 0.3 3/16" Shaft
(3/4" Stack)

Fan Motors - Evaporator

BOC Part No. Brand
Watts
Amps
Rotation
Description
NET4C10ZVN001 G.E. 9 0.28 CW Low temp evaporator fan motor, hub mount fans, suit island freezer cases
R51000082 300mm (12") Evaporator fan assembly Suits most brands of coolroom evaporators ie. External rotor motor
R51000010 353mm (14") Evaporator fan assembly Suits most brands of evaporators
ie. External rotor type motor

BETTS Fan Motors

BOC Part No. Voltage
(phase)
Watts RPM Speeds Shaft
dia.
Rotation Capacitor (MFD) Body
enclosure
Single Shaft Models
808554LTB-A80 240(1) 180 1340 1 1/2" Reversible 4 Total enclosed
(144 mm dia)
8061S120-80 240(1) 370 900 1 1/2" Reversible 8 Total enclosed
(144 mm dia)
Double Shaft Model (Resilient mount)
8061S082-80 240(1) 550 1370 2 1/2" (Twin) Reversible 15 Open
(144 mm dia.)

THERMON Heating Cable - Self-Regulating

Description Part No. Power output
W/ft (W/m)
Length
(per box)
10 watt heater cable (Braided) FLX-10-2 10 (33) 10m
Termination kit SX-Term-1BC - -

Frost-Free Fan Motors

BOC Part No. Brand Rotation Shaft Dia. Volts Amps Description
J03RF03 JRM (3/8" stack) CW 1/8'' 240 0.11 Centre mount
(suit Kelvinator and others

Electric Motors

Electric motors used for direct coupling to small fan impellers are normally single phase shaded pole type in the approximate range of 6 to 150 watts.

Their characteristics are low starting torque, low efficiency and power factor and high slip. Unless specially wired they are non-reversing. Their main advantages are simple construction and low cost. They are also adaptable for modulating speed control by winding extra coils and taps into the main field or by adding impedance externally as with a series choke. Their low starting torque is not a particular disadvantage as starting torque required for propeller fans is usually low. Designs now available with double ended shaft makes them bi-directional simply by turning the motor around to choose clockwise or anti-clockwise rotation.

BETTS Fan Motors

Double Shaft Motors

BOC Part No. Watts Amps Rotation Replaces
50D501-80A 10 0.3 Bi-directional D101, D102, D105, D106, D142, D143, BP26A/C, BG`1A/C,BG2A/C, 30D501-21A/C to 26A/C,73C, 72A, 70A, 76C, 78C, 79C, 80C, 30D501 Series, BDS13-1A & 1C BDD13-1A, BP139/3C
50D502-80A 20 0.50 Bi-directional 30D503-77A & 71A, 61A/C BDD20-1A, BDS20-1A/C
50D503-80A 40 0.75 Bi-directional D152, D156, BG7A, 30D503-21A to 26A, 75A, 76A, 70C, 71C. 30D503-74A, 78A, 79A, BDS40-1A & 1C, BDD40-1A, BG3A, BP112C, BP163/1A, 30D503 series

415 volt x 1 phase Single Shaft Motors

BOC Part No. Watts Amps Rotation Replaces
50D509-22A 40 0.4 ACW Used on Kirby units.
Replaces BG4A.

Single Shaft "Plastic Hub Mount"

BOC Part No. Watts Amps Rotation Replaces
50D501-81A 13 0.4 ACW Replaces 30D501-70A.

RE Relays and Overloads

BOC Part No. Replaces Kirby
Part No.
Suits
KT1R ME556-4 1/12 hp
KT2R ME535-3, ME556-3 1/8 hp
KT3R ME535-2, ME556-2 1/6 hp
KT4R ME535-1, ME556-1 1/5 hp
KT5R ME556-5 Small 1/4 hp
KT12R ME535-6, ME556-6 Large 1/4 hp
KT35R ME732-10 Small 1/3 hp
KT36R ME732-4 Large 1/4 hp MBP
KT42R ME785-17 1/3 or 1/2 hp
KT43R ME785-18 3/4 hp
KT44R ME727-10 3/4 hp
KT45R ME727-7 1 hp

Overloads


BOC Part No. Replaces Kirby
Part No.
Suits
KT1P ME380-12 1/12 hp
KT2P ME380-8 1/8 hp
KT3P ME380-13 1/6 hp
KT4P ME380-9, ME380-14, ME380-24 1/6 hp
KT5P ME380-10, ME380-22, ME380-35 1/5 hp
KT6P ME380-11 1/4 hp
KT43P ME781-6 Large 1/3 hp
KT44P ME781-5 1/2 hp
KT45P ME781-9 3/4 hp
KT60P ME781-11 3/4 hp
KT62P ME380-31 1/4 hp
KT64P ME781-12 1 hp
KT65P ME781-10 1 hp
KT66P ME380-34 Small 1/3 hp

Evaporative Cooler Pumps

BOC Part No. Brand Application Flow rate
L/min @ 1m head
Dimensions
(mm)
EBM25JB ZIEHL-ebm Domestic 25 230 x 120
EBM40JB ZIEHL-ebm Domestic/Commercial 35 225 x 105

OLMO Universal Fan/Motor/Guard Assemblies

BOC Part No. Model number Fan blade
diam. (mm)
No. of
poles
Voltage
4IEN060K R09R-3028A-4M-2506/6 300 4 240V
4IRN085 R09R-3532A-4M-4213/6A 350 4 240V
4KRN015 R11R-4030A-4M-5728 400 4 240V
4MRN043 R13R-4530A-4M-5039 450 4 240V
4MRN003 R13R-4530A-4T-3536/1 450 4 415V
4MRN049 R13R-5030A-4M-7055 500 4 240V
4MRN001 R13R-5030A-4T-7065/1 500 4 415V
4MRN065 R13R-5630A-6M-7034 560 6 240V
4MRN005 R13R-5630A-6T-5032/1 560 6 415V
4MRN125 R13R-6330A-6M-7050 630 6 240V
4MRN116 R13R-6330A-6T-7045/1 630 6 415V

Fan Motor Mounting Brackets & Bearings

Description Part No. Application
Universal motor bearing kits 391-074-01 Suits both Betts and Brinsmead

ZIEHL-ebm Square Fan Motors - Hub Mount

BOC Part No.

Watts

Amps

Description

M4Q045-CA03-38

10

0.28

General purpose ‘square’ fan motors

M4Q045-CF01-38

16

0.45

General purpose ‘square’ fan motors

M4Q045-EA01-38

25

0.66

General purpose ‘square’ fan motors

M4Q045-EF01-38

34

0.90

General purpose ‘square’ fan motors

Acson Air Curtains

BOC Part No.
Speed Air flow
(l/sec.)
Effective
curtain
height (m)
Motor data

Dimensions (mm)

Weight
(kg)
Watts Volts Length Height Depth
ACA038A 1 214 2.5 90 240 912 203 207 17
ACA048A 1 278 2.5 115 240 1214 203 207 21
ACA410A 2 565 3.0 180 240 1210 265 265 30